{"id":2319,"date":"2024-04-02T17:06:18","date_gmt":"2024-04-02T15:06:18","guid":{"rendered":"https:\/\/www.beta-strumentazione.it\/prodotto\/betacap60-3g\/"},"modified":"2025-02-13T13:13:49","modified_gmt":"2025-02-13T12:13:49","slug":"betacap60-3g","status":"publish","type":"cpt_portfolio","link":"https:\/\/www.beta-strumentazione.it\/en\/product\/betacap60-3g\/","title":{"rendered":"BetaCAP60-3G"},"content":{"rendered":"<section class=\"portfolio_page_details_wrap\"><div class=\"portfolio_page_details\"><span class=\"portfolio_page_details_item\"><span class=\"portfolio_page_details_item_title\">Technical bulletin<\/span><a href=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP60-3G-NEW-ENG1.pdf\" class=\"portfolio_page_details_item_value\" target=\"_blank\"><span class=\"portfolio_page_details_item_icon sc_icon_type_icons icon-arrow-down-1\"><\/span>Download<\/a><\/span><span class=\"portfolio_page_details_item\"><span class=\"portfolio_page_details_item_title\">Automatic calculation of the viscosity of mixtures:<\/span><a href=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/ViscosityCalculation_ENG.xls\" class=\"portfolio_page_details_item_value\" target=\"_blank\"><span class=\"portfolio_page_details_item_icon sc_icon_type_icons icon-arrow-down-1\"><\/span>Download<\/a><\/span><span class=\"portfolio_page_details_item portfolio_page_details_share\"><span class=\"portfolio_page_details_item_title\">Share<\/span><span class=\"portfolio_page_details_item_value\"><div class=\"socials_share socials_size_tiny socials_type_list socials_dir_horizontal socials_wrap\"><span class=\"social_items inited\"><a class=\"social_item social_item_popup\" href=\"\/\/twitter.com\/intent\/tweet?text=BetaCAP60-3G&amp;url=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap60-3g\/\" data-link=\"\/\/twitter.com\/intent\/tweet?text=BetaCAP60-3G&amp;url=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap60-3g\/\" data-count=\"twitter-new\" data-cmp-ab=\"2\"><span class=\"social_icon social_icon_twitter-new sc_icon_type_icons\"><span class=\"icon-twitter-new\"><\/span><\/span><\/a><a class=\"social_item social_item_popup\" href=\"\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap60-3g\/\" data-link=\"\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap60-3g\/\" data-count=\"facebook-1\"><span class=\"social_icon social_icon_facebook-1 sc_icon_type_icons\"><span class=\"icon-facebook-1\"><\/span><\/span><\/a><a class=\"social_item\" href=\"mailto:?subject=BetaCAP60-3G&amp;body=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap60-3g\/\" target=\"_blank\" data-count=\"share-email\" data-cmp-ab=\"2\"><span class=\"social_icon social_icon_share-email sc_icon_type_icons\"><span class=\"icon-share-email\"><\/span><\/span><\/a><\/span><\/div><\/span><\/span><\/div><\/section>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:55%\">\n<p class=\"wp-block-paragraph\">BetaCAP60-3G is a double diluter : it contains two modules CAP30 and an interface cirduit allowing to distribute three gas inputs over both above modules. The first consequence of this structure is the possibility to handle true cross sensitivity tests in addition to linearity tests. Something similar to a cross sensitivity test is also done with single line diluters, but differently from the norms request the cross sensitive component response is tested just with measured component at zero level.<br>Another improvement over the previous models of the BetaCAP family is a more powerful electronics : faster and with 16 bit resolution. Those features are improving the pressures stability and generally the analogic processing ( the self-test procedure we will see later get big benefits from that).<br>Each one of the three gas inputs (two gases to be diluted and one diluting gas) are addressed to the two dilution modules in a way depending on the two dilution rates : both dilutions are free from zero to 100% The obvious limit is that Kdil.1 + Kdil.2 \u2264 100%<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"606\" src=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G-1024x606.jpg\" alt=\"\" class=\"wp-image-746\" srcset=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G-1024x606.jpg 1024w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G-300x178.jpg 300w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G-768x455.jpg 768w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G-370x219.jpg 370w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G-840x497.jpg 840w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G-410x243.jpg 410w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/Sch-CAP60-3G.jpg 1079w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:45%\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"3115\" height=\"3500\" src=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865.png\" alt=\"\" class=\"wp-image-745\" srcset=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865.png 3115w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-267x300.png 267w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-911x1024.png 911w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-768x863.png 768w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-1367x1536.png 1367w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-1823x2048.png 1823w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-370x416.png 370w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-840x944.png 840w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/04\/DSC00865-410x461.png 410w\" sizes=\"(max-width: 3115px) 100vw, 3115px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Also BetaCAP60-3G is managed through his mathematical representation : it was more complex to design the firmware because the three pressure setpoints comes from the solution of a sistem with three equations. of seconf degree. In addition, the diluter logics includes two dilution ratios and recovering the way of saturating the available capillaries<br>Another difference with the CAP30 family is about viscosities : iWith BertaCAP30, viscosities of mixtures are calculated off-line by a spreadsheet and written by the User in the diluter memory. With BetaCAP60-3G the calculation (by Reichenberg) is in on-line by the firmware : each test gas must be qualified with components list and relevant concentrations and the diluter does all what it remains.<br>The lucky combination of having in the diluter two virtually equal capillaries blocks, grouped in a particolar mode, and our fcontinuous research of unforeseen opportunities, did favour the development of an interesting self-test procedure. When equal pressures are applied, all nearly equal capillaries groups are crossed by a flow that must be proportional to the number of capillaries in the group. The self-test procedure just check that, calculating the deviations with the best resolution is allowed, much higher than with traceable processes. Interested people can find a detailed presentation about SELF-TEST at the SELF-TEST procedure Download. To run this procedure it\u2019s necessary to have installed the optional CAL60 module (a multi-range flow meter) and a free PC program.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Technical Specifications<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Dilution details<\/strong><\/td><td><\/td><\/tr><tr><td>Dilutions range (Step)<\/td><td>from 0\/60 to 60\/60 step1\/60 (1,667%)<\/td><\/tr><tr><td>Dilution range (Continuous)<\/td><td>Continuous coverage from 0,5\/60 to 59,5\/60 and step zero and span<\/td><\/tr><tr><td>Accuracy<\/td><td>&lt; 0,15 % of the read value<\/td><\/tr><tr><td>Repeatability<\/td><td>&lt; 0,10% of the read value<\/td><\/tr><tr><td><strong><strong>Gas contacted materials<\/strong><\/strong><br><\/td><td><\/td><\/tr><tr><td>Std. Plastics (Standard)<\/td><td>PVDF, PEEK, Teflon PFA, Viton, Kalrez, Glass, AISI 316L<\/td><\/tr><tr><td>All stainless steel (Option)<\/td><td>acciaio AISI 316L, PEEK, Viton, Kalrez, Vetro<\/td><\/tr><tr><td><strong><strong><strong>Diluted gas output flow<\/strong><\/strong><\/strong><br><\/td><td><\/td><\/tr><tr><td>Std. Plastics (Standard)<\/td><td>PVDF, PEEK, Teflon PFA, Viton, Kalrez, Glass, AISI 316<\/td><\/tr><tr><td>All stainless steel (Option)<\/td><td>acciaio AISI 316L, PEEK, Viton, Kalrez, Vetro<\/td><\/tr><tr><td><strong><strong><strong>Diluted gas output flow<\/strong><\/strong><\/strong><br><\/td><td><\/td><\/tr><tr><td>Low size (1 hole \/ capillary)<\/td><td>nearly 4 L\/min. @ 2000 hPa (by the user from 0,4 L\/min @ 200 hPa)<\/td><\/tr><tr><td>High Size (3 holes \/ capillary)<\/td><td>nearly 6 L\/min. @ 2000 hPa (0,6 L\/min @ 200 hPa) upon request<\/td><\/tr><tr><td><strong><strong><strong><strong>Sizes<\/strong><\/strong><\/strong><\/strong><br><\/td><td><\/td><\/tr><tr><td>BetaCAP60-3G CP (Compact)<\/td><td>430 X 244 X 341 mm \u2013 Weigth : 8 kg (plastics) \u2013 10 kg (steel)<\/td><\/tr><tr><td>BetaCAP60-3g (19\u201d Rack)<\/td><td>Rack 19\u201d std. \u2013 h 3U \u2013 prof. 250 (with protective case upon request)<\/td><\/tr><tr><td><strong>Power supply<\/strong><\/td><td>From 100 to 240 Vac 50\/60 Hz<br><\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>BetaCAP60-3G is a double diluter : it contains two modules CAP30 and an interface cirduit allowing to distribute three gas inputs over both above modules. The first consequence of this&hellip;<\/p>\n","protected":false},"author":1,"featured_media":2321,"comment_status":"closed","ping_status":"closed","template":"","cpt_portfolio_group":[],"class_list":["post-2319","cpt_portfolio","type-cpt_portfolio","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio\/2319","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio"}],"about":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/types\/cpt_portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/comments?post=2319"}],"version-history":[{"count":4,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio\/2319\/revisions"}],"predecessor-version":[{"id":2918,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio\/2319\/revisions\/2918"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/media\/2321"}],"wp:attachment":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/media?parent=2319"}],"wp:term":[{"taxonomy":"cpt_portfolio_group","embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio_group?post=2319"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}