{"id":2316,"date":"2024-03-26T12:07:12","date_gmt":"2024-03-26T11:07:12","guid":{"rendered":"https:\/\/www.beta-strumentazione.it\/prodotto\/betacap30\/"},"modified":"2025-02-19T10:44:41","modified_gmt":"2025-02-19T09:44:41","slug":"betacap30","status":"publish","type":"cpt_portfolio","link":"https:\/\/www.beta-strumentazione.it\/en\/product\/betacap30\/","title":{"rendered":"BetaCAP30"},"content":{"rendered":"<section class=\"portfolio_page_details_wrap\"><div class=\"portfolio_page_details\"><span class=\"portfolio_page_details_item\"><span class=\"portfolio_page_details_item_title\">Technical bulletin<\/span><a href=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-NEW-ENG1.pdf\" class=\"portfolio_page_details_item_value\" target=\"_blank\"><span class=\"portfolio_page_details_item_icon sc_icon_type_icons icon-arrow-down-1\"><\/span>Download<\/a><\/span><span class=\"portfolio_page_details_item\"><span class=\"portfolio_page_details_item_title\">Automatic viscosity calculation of mixtures:<\/span><a href=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/ViscosityCalculation_ENG.xls\" class=\"portfolio_page_details_item_value\" target=\"_blank\"><span class=\"portfolio_page_details_item_icon sc_icon_type_icons icon-arrow-down-1\"><\/span>Download<\/a><\/span><span class=\"portfolio_page_details_item portfolio_page_details_share\"><span class=\"portfolio_page_details_item_title\">Share<\/span><span class=\"portfolio_page_details_item_value\"><div class=\"socials_share socials_size_tiny socials_type_list socials_dir_horizontal socials_wrap\"><span class=\"social_items inited\"><a class=\"social_item social_item_popup\" href=\"\/\/twitter.com\/intent\/tweet?text=BetaCAP30&amp;url=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap30\/\" data-link=\"\/\/twitter.com\/intent\/tweet?text=BetaCAP30&amp;url=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap30\/\" data-count=\"twitter-new\" data-cmp-ab=\"2\"><span class=\"social_icon social_icon_twitter-new sc_icon_type_icons\"><span class=\"icon-twitter-new\"><\/span><\/span><\/a><a class=\"social_item social_item_popup\" href=\"\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap30\/\" data-link=\"\/\/www.facebook.com\/sharer\/sharer.php?u=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap30\/\" data-count=\"facebook-1\"><span class=\"social_icon social_icon_facebook-1 sc_icon_type_icons\"><span class=\"icon-facebook-1\"><\/span><\/span><\/a><a class=\"social_item\" href=\"mailto:?subject=BetaCAP30&amp;body=https:\/\/www.beta-strumentazione.it\/en\/product\/betacap30\/\" target=\"_blank\" data-count=\"share-email\" data-cmp-ab=\"2\"><span class=\"social_icon social_icon_share-email sc_icon_type_icons\"><span class=\"icon-share-email\"><\/span><\/span><\/a><\/span><\/div><\/span><\/span><\/div><\/section>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h2 class=\"wp-block-heading\">Duluter description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">BetaCAP30 is the first born in the BetaCAP family, and akso is the one having got the more substantial evoluttions up to now<br>His engine is a set of 30 capillaries selected to be nearly equal and grouped in 5 groups to simplify the circuit of gas distribution to send the gas to be diluted and diluting gas to the various capillaries. Different capillaries partitions allow setting 30 different dilution rates step by step\u201d. Differential pressures applied to gases crossing capillaries groups are measured and controlled electronically (PID logic and PWM driving to the relevant valves) : this allows applying calculated set points  to proportional valves. The relative simplicity of the diluter functional diagram and of the physics of gas flow through capillaries did allow writing an accurate \u201cdiluter transfer function\u201d that automatically controls the BetaCAP30 activity according to simple commands by the user.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1881\" height=\"2560\" src=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-scaled.jpg\" alt=\"\" class=\"wp-image-2866\" srcset=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-scaled.jpg 1881w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-220x300.jpg 220w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-752x1024.jpg 752w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-768x1045.jpg 768w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-1129x1536.jpg 1129w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-1505x2048.jpg 1505w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-370x504.jpg 370w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-840x1143.jpg 840w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/CSC00885-410x558.jpg 410w\" sizes=\"(max-width: 1881px) 100vw, 1881px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"980\" height=\"625\" src=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/Schema-CAP30-ITA.jpg\" alt=\"\" class=\"wp-image-327\" srcset=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/Schema-CAP30-ITA.jpg 980w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/Schema-CAP30-ITA-300x191.jpg 300w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/Schema-CAP30-ITA-768x490.jpg 768w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/Schema-CAP30-ITA-370x236.jpg 370w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/Schema-CAP30-ITA-840x536.jpg 840w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/03\/Schema-CAP30-ITA-410x261.jpg 410w\" sizes=\"(max-width: 980px) 100vw, 980px\" \/><\/figure>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"296\" height=\"140\" src=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2025\/02\/CAP-1-2-4-FORI-RIDRIDb-ENG.jpg\" alt=\"\" class=\"wp-image-2885\" style=\"width:630px;height:auto\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1438\" src=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1.jpg\" alt=\"\" class=\"wp-image-2335\" srcset=\"https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1.jpg 2560w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-300x169.jpg 300w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-1024x575.jpg 1024w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-768x431.jpg 768w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-1536x863.jpg 1536w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-2048x1150.jpg 2048w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-370x208.jpg 370w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-1290x725.jpg 1290w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-840x472.jpg 840w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-410x230.jpg 410w, https:\/\/www.beta-strumentazione.it\/wp-content\/uploads\/2024\/08\/CAP30-Steel1-scaled-1-270x152.jpg 270w\" sizes=\"(max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Here it\u2019s shown the \u201call steel AISI316L option\u201d : just the solenoid valves bodies are made by PEEK.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading\">Diluter description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">This approach allows integrating the diluter with more useful functions : the different viscosities compensation, the certified deviations correction and, last but not least, the continuous coverage of the dilution range : no more just step by step with capillaries. The \u201ccontinuous dilution mode\u201d also makes wider the dilution range extending it down to 0,5\/30 (double width comparing it with 1\/30 !) It requires the user sets the target diluted concentration in place of setting the dilution ratio.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on the application type, BetaCAP30 can be supplied in different versions :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Max diluted gas flow: different values can be supplied alternately by using capillaries with 1, 3 or 4 holes. Doing that, capillaries rules are stable : just capillaries number changes, not the size. (measures indicated in drawings are in tenths of mm).&nbsp; The user is free to set different flows in the range 10%&#8230;.100% of the max. range supplied<\/li>\n\n\n\n<li>Gas contacted materials: the standard construction is with PVDF (an highly resistant to corrosion fluorinated plastics. &nbsp; &nbsp; In case of handling toxic or explosive gases, we suggest the \u201call steel\u201d version with AISI316L stainless steel, where the risk of cracking in tubes or fittings is more&nbsp; remote.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/li>\n\n\n\n<li>Casing type:&nbsp;depending on the type of moving&nbsp; (portable or rack mounted) BetaCAP30 can be supplied in a compact and rugged plastic case with handle (ext. Size: 27 x 24,6 x 17,4 cm) or in a 19\u201d rack drawer 3HU with or without an external shocks protection.<\/li>\n\n\n\n<li>The two pressures (gas to be diluted and diluting gas) are controlled electronically by a PID circuit with std. Dev. \u00b1 1mBar over 2.000 to allow applying some special function as Gases viscosities compensation, certified errors correction and continuous diluted gas concentration setting over the entire dilution range The controller variables are the differential pressures input\/output on gas to be diluted side and on diluting gas side. A common mode pressures deviation has a very small influence on dilution, but a differential deviation induces important dilution deviations.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Pressures calibration is an important task : it&#8217;s made applying an external pressure to all the pressure meters in one time. This assures differential pressures alignement and absolute pressurers calibration.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Differential pressures can have high influence on the dilution but,calibrating zero and span of the three pressures together assures a perfect responces overlapping independently from the applied pressure reference.. This have effects in absolute pressures calibration : hopefully a common mode deviation  have very small consiquences on the dilution accuracy<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The dilution module is made by two flat surface shells : capillaries have one half in one and one half in the other shell, with an o-ring in the middle . The other components you can see in the functional diagram are fixed on the external shell surface and the many pneumatic connections are got by crossing holes.&nbsp; This construction leads to a module very compact and also very rugged : the big shocks due to frequent travels never did cause a capillary breakage, despite they are made by glass , because with glass oxidation is not allowed.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-775cae15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h2 class=\"wp-block-heading\">Technical features<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-regular\"><table><tbody><tr><td><strong>Dilution details<\/strong><\/td><td><\/td><\/tr><tr><td>Dilutions range (Step)<\/td><td>from 0\/30 to 30\/30 step1\/30 (= 3,33%)<\/td><\/tr><tr><td>Dilution range (Continuous)<\/td><td>Uninterrupted coverage from 0,5\/30 to 29,5\/30 zero and span included<\/td><\/tr><tr><td>Accuracy<\/td><td>&lt; 0,20% of the read value<\/td><\/tr><tr><td>Repeatability<\/td><td>&lt; 0,10% of the read value<\/td><\/tr><tr><td><strong>Gas contacted materials<\/strong><br><\/td><td><\/td><\/tr><tr><td>Std. Version: Plastics<\/td><td>PVDF    <\/td><\/tr><tr><td>Optional Stainless steel<\/td><td>AISI316L<\/td><\/tr><tr><td><strong><strong>Diluted gas flow rate<\/strong><br><\/strong><\/td><td><\/td><\/tr><tr><td>Low size              <\/td><td>1 hole\/capillary Max flow = 2 NL\/min. Applied flow : set by the user &lt; 2NL\/min<\/td><\/tr><tr><td>Tall size<\/td><td>3 holes\/capillary Max flow = 6 NL\/min. Applied flow : set by the user &lt; 6NL\/min<\/td><\/tr><tr><td><strong>Dimensions<\/strong><br><\/td><td><\/td><\/tr><tr><td>BetaCAP30 CP (Compact)<\/td><td>27 x 24,6 x 17,4 cm         <\/td><\/tr><tr><td>BetaCAP30RK<\/td><td><br>485 x 136 x 295 mm<\/td><\/tr><tr><td><strong>Electrical supply<\/strong><br><\/td><td><br>100 &#8230;240 Vac  50VA<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Duluter description BetaCAP30 is the first born in the BetaCAP family, and akso is the one having got the more substantial evoluttions up to nowHis engine is a set of&hellip;<\/p>\n","protected":false},"author":1,"featured_media":2971,"comment_status":"closed","ping_status":"closed","template":"","cpt_portfolio_group":[],"class_list":["post-2316","cpt_portfolio","type-cpt_portfolio","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio\/2316","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio"}],"about":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/types\/cpt_portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/comments?post=2316"}],"version-history":[{"count":12,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio\/2316\/revisions"}],"predecessor-version":[{"id":2902,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio\/2316\/revisions\/2902"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/media\/2971"}],"wp:attachment":[{"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/media?parent=2316"}],"wp:term":[{"taxonomy":"cpt_portfolio_group","embeddable":true,"href":"https:\/\/www.beta-strumentazione.it\/en\/wp-json\/wp\/v2\/cpt_portfolio_group?post=2316"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}